Lots of rain followed by bright sun over the past couple of days, but FC is holding, as is CYA. TA reduction still in process. Will lower SWCG production to 60%.
32 oz of 31.45% (20º Be) Muriatic Acid
18.5
FC
7.8
pH
100
TA
70
CYA
32 oz of 31.45% (20º Be) Muriatic Acid
18.5
FC
8.0
pH
100
TA
70
CYA
Algae must be gone - OCLT was passed and FC is rising again. Will adjust cell to 60%, down from 75%, as FC needs to drop. Wait to address TA until FC is down, as even though I’m using R0007, I don’t completely trust the pH results given the amount of MA that has been added. CYA shows 80, but low confidence in this result. Cloudy skies so the lighting is low. I’m sure this also helped with FC.
22.5
FC
7.6
pH
110
TA
80
CYA
No LC additions in several days. FC increasing with SWCG set at 75%. Reducing runtime from 24 hours to 18 hours (3am - 9pm). High MA dosing to bring TA down by bringing pH down.