The Accurso Ranch

Volume: 26000 Gallons
Build Type: Plaster
Replaced SWCG cell with new one (not warranty replacement)
1 gal of 31.45% (20º Be) Muriatic Acid
7.7
pH
74 °F
TEMP
-0.12
CSI
7.7
pH
75 °F
TEMP
-0.17
CSI
Cleaned SWCG again.
7.6
pH
77 °F
TEMP
-0.22
CSI
7.5
pH
76 °F
TEMP
-0.37
CSI
1 gal of 14.5% Muriatic Acid
4.0
FC
0.0
CC
7.7
pH
90
TA
77 °F
TEMP
-0.13
CSI
7.5
pH
77 °F
TEMP
-0.29
CSI
7.3
pH
79 °F
TEMP
-0.42
CSI
7.2
pH
78 °F
TEMP
-0.53
CSI
1 gal of 14.5% Muriatic Acid
7.5
pH
78 °F
TEMP
-0.24
CSI
Will continue to monitor pH and add acid to reach a lower TA. Will continue to maintain CSI at -0.3 to 0.0 to avoid SWCG cell scaling.
4.5
FC
0.5
CC
7.4
pH
100
TA
79 °F
TEMP
-0.33
CSI
0.5 gal of 14.5% Muriatic Acid
7.5
pH
79 °F
TEMP
-0.16
CSI
0.5 gal of 14.5% Muriatic Acid
7.6
pH
82 °F
TEMP
-0.05
CSI
Reduced borates level to estimated 10ppm since haven’t added any in 3 years.
10
BOR
-0.10
CSI
7.6
pH
82 °F
TEMP
-0.13
CSI
Cleaned SWCG cell again. Cell was crusted up pretty good even though pH has been lower along with CSI negative.
7.5
pH
82 °F
TEMP
-0.20
CSI
4.0
FC
0.0
CC
7.4
pH
110
TA
79 °F
TEMP
-0.29
CSI
110
TA
-0.55
CSI
4.5
FC
0.0
CC
-0.46
CSI
7.1
pH
80 °F
TEMP
-0.46
CSI
6.9
pH
79 °F
TEMP
-0.65
CSI
Attempting to lower TA. Adding acid to drop pH to 7.2. Will let pH drift up naturally then drop it with acid again. Per TFP, keep CSI between -0.3 and 0.0 to avoid scaling. Will need to lower pH to do that. Lowering TA will help with keeping pH under control. FYI: Home Depot only has “weak” 14.5% acid now. Got 31.45% acid at Ace for a better price.
1 gal of 14.5% Muriatic Acid
3.5
FC
0.0
CC
8.0
pH
130
TA
80 °F
TEMP
0.30
CSI
Clean Cell light still coming on. Noticed a lot of calcium buildup again. Cleaned cell with vinegar /water solution (50/50). Called Circupool to get price on replacement cell.
2.0
FC
0.0
CC
8.0
pH
78 °F
TEMP
0.17
CSI
Backwashed
Party yesterday with lots of swimmers. SWCG has been acting up. Cycling power gets it going at 4 lights otherwise Clean Cell and one flashing green light is on.
3.0
FC
0.0
CC
7.8
pH
81 °F
TEMP
0.10
CSI
3400
SALT
0.07
CSI
6.5
FC
0.0
CC
7.8
pH
81 °F
TEMP
0.09
CSI
1 gal of 31.45% (20º Be) Muriatic Acid
40 lbs of Salt
3000
SALT
0.37
CSI
Adjusted spd2 up 1h to 14h.
4.0
FC
0.0
CC
8.2
pH
80 °F
TEMP
0.36
CSI
Backwashed
Filter Pressure:15
Backwashed
Filter Pressure:15
SWCG “low salt” light on. Salt tests fine at 3200 ppm. May be cleared by backwashing filter.
4.5
FC
0.0
CC
8.2
pH
3200
SALT
82 °F
TEMP
0.38
CSI
Clean cell light on. Cleaned cell with zip tie and water blast. Light out now.
60
CYA
0.36
CSI
5.0
FC
0.0
CC
8.2
pH
80 °F
TEMP
0.39
CSI
3200
SALT
0.30
CSI
Vacuumed
6.5
FC
0.5
CC
8.1
pH
78 °F
TEMP
0.31
CSI
8.5
FC
0.0
CC
8.0
pH
50
CYA
73 °F
TEMP
0.19
CSI
5 lbs of Dry Stabilizer
Checked salt it was at 2800 ppm. Added salt and the “low salt“ light came on added CYA and FC came up. Now have all green lights after adding a second bag of salt and PPM is at 3000. Clean cell light is also off now.
6.5
FC
0.0
CC
8.0
pH
3000
SALT
72 °F
TEMP
0.21
CSI
Vacuumed Backwashed
80 lbs of Salt
FC still dropping. Increased spd2 13h —> 15h. Will add salt since test gave only 2800ppm
40
CYA
0.35
CSI
3.5
FC
0.0
CC
8.2
pH
110
TA
300
CH
2800
SALT
70 °F
TEMP
0.30
CSI
Clean Cell light still on. 4th light blinking. Cleaned pump screen and increased Speed2 time 12h —>13h since FC only 4ppm.
4.0
FC
8.1
pH
70 °F
TEMP
0.49
CSI
4.5
FC
0.0
CC
0.36
CSI
3.5
FC
0.5
CC
0.36
CSI
4.0
FC
0.0
CC
8.0
pH
66 °F
TEMP
0.36
CSI
Weather warmed up. FC too low. Set SWCG to 100% and changed spd2 time from 6h to 10h.
2.0
FC
0.0
CC
8.1
pH
66 °F
TEMP
0.44
CSI
6.5
FC
0.0
CC
8.0
pH
51 °F
TEMP
0.23
CSI
Backwashed
Filter Pressure:15
9.0
FC
0.5
CC
0.40
CSI
8.2
pH
52 °F
TEMP
0.40
CSI
Reduced Spd2 time from 10h to 6h. Cold water light on.
SWCG: Cold Water light on
Clean Cell light on. Blasted cell with hose and got most of calcium buildup out. Reinstalled and light out.
7.6
pH
74 °F
TEMP
0.04
CSI
8.5
FC
0.0
CC
8.2
pH
130
TA
75 °F
TEMP
0.61
CSI
1 gal of 31.45% (20º Be) Muriatic Acid
Clean Cell light on. Cleaned cell with nylon zip tie and water blast. Light off now.
Low Salt light was lit. Checked salt level: 3400ppm per drop test, 3150ppm per meter, Ok on both. Pressure was over 20psi on Spd1, so backwashed filter. Now light is out and 15psi at Spd1.
Backwashed
Filter Pressure:15
6.0
FC
0.5
CC
8.2
pH
3400
SALT
77 °F
TEMP
0.49
CSI
6.5
FC
0.0
CC
8.1
pH
76 °F
TEMP
0.45
CSI
8.5
FC
0.0
CC
8.1
pH
83 °F
TEMP
0.47
CSI
9.0
FC
0.5
CC
8.0
pH
82 °F
TEMP
0.41
CSI
Backwashed
Filter Pressure:15
8.5
FC
0.5
CC
7.9
pH
84 °F
TEMP
0.35
CSI
Reduced SWCG Spd2 to 10h (was 11h) due to high FC.
60
CYA
0.32
CSI
11.5
FC
0.0
CC
7.9
pH
81 °F
TEMP
0.32
CSI
Backwashed
Filter Pressure:15
2nd new pH meter (pH and Salt ppm).
7.8
pH
3200
SALT
74 °F
TEMP
0.22
CSI
New pH meter (uncalibrated).
7.7
pH
78 °F
TEMP
0.15
CSI
4 lbs of Dry Stabilizer
40
CYA
0.45
CSI